Lab

Multimeter simulator: learn to use a multimeter with live circuits

Wire a circuit, turn the dial, touch the probes to it and read the display. Practise on the DCACLab multimeter with live circuits, without risking a real meter.

Open the lab

The circuits on this page work without an account. On a computer or tablet the full lab is limited without an account; a free account lets you try it in full first. Saving needs a plan. Create a free account

How to use a multimeter in 5 steps

  1. Pick what you measure and turn the dial to it: volts, amps, ohms or continuity (the dial also has a diode test).
  2. Pick a range above the value you expect. A range that is too low shows OL, for overload.
  3. Check the probes: black in COM, red in V Ω, and for current the red probe in the A jack. In the simulator they are plugged in already; you drag their tips onto the circuit.
  4. Touch the circuit the right way: across a part for volts, in line with it for amps, across a part on its own for ohms.
  5. Read the display. A minus sign means the red probe is on the negative side.

Measure voltage (voltmeter)

A voltmeter goes in parallel: one probe on each side of the part. When a 10 V battery drives two 1 kΩ resistors in series, each one drops half: 10 V × 1 kΩ / 2 kΩ = 5 V.

Below, the meter is on its 20 V range, red probe on the more positive end of the right-hand resistor.

Preview of Measure Voltage with a Multimeter: 10 V Across Two 1 kΩ Resistors
Open in the lab Embed Run the circuit right here. To edit it in the full lab, sign in; free accounts have a time limit there.
  1. Read the display: 5.000 V.
  2. Turn the dial to the 200 V range: 5.00. A higher range shows fewer decimals.
  3. Turn it to the 2 V range: OL, because 5 V is over range.
  4. Swap the probes: -5.000. Nothing breaks.

Measure current (ammeter)

An ammeter goes in series: break the loop and let the meter close the gap.

In the circuit below the same 10 V battery and two 1 kΩ resistors carry 10 V / 2 kΩ = 5 mA, and the lab's inline ammeter sits in the return wire.

Preview of Measure Current with an Ammeter: 5 mA in a Series Loop
Open in the lab Embed Run the circuit right here. To edit it in the full lab, sign in; free accounts have a time limit there.
  1. Read the meter: 5.00 mA.
  2. Turned the other way round in the loop, the same meter reads -5.00 mA: the sign shows the direction of the current.

To measure current with the digital multimeter, turn the dial to a current range and use the red probe in the A jack instead of the one in V Ω; the black one stays in COM. In a 10 V loop with two 1 kΩ resistors it reads 5.000 on the 20 mA range and 5.00 on the 200 mA range, and the 2 mA range shows OL.

Never put an ammeter across a part: it has almost no resistance, so it shorts the part out. Across one resistor of that 10 V loop it would carry 10 V / 1 kΩ = 10 mA, twice the normal current.

Measure resistance (ohmmeter)

An ohmmeter sends its own small current through the part, so the power must be off, and the part should be out of the circuit, or other paths change the number. On the 2k range a 1 kΩ resistor alone reads 1.0000 (kΩ). The 200 range shows OL, and the 20k range shows 1.000.

Put a second 1 kΩ resistor across it and the meter reads .5000, that is 500 Ω: 1 kΩ × 1 kΩ / 2 kΩ.

Try it: Measure resistance: one 1 kΩ resistor, then two in parallel

Continuity test

Continuity checks whether two points are joined. Turn the dial to the speaker symbol and touch the probes to both points: a closed path reads close to 0 and beeps; a gap reads OL. In the continuity circuit the probes sit on a toggle switch: open, it reads OL; click the switch closed and it reads 0.00 and beeps.

Try it: Continuity test on a switch

Ranges, OL and polarity

What the simulator does and does not model

The DCACLab digital multimeter reads as an ideal meter: on volts it draws no current, and on amps it adds nothing in series. A typical real digital meter has about 10 MΩ of input resistance and drops a small burden voltage on current ranges. The lab does not match any particular real meter.

The lab's inline voltmeter part has a 1 MΩ input. Across one half of a 1 MΩ + 1 MΩ divider on 10 V it reads 3.33 V, not 5 V: in parallel it turns that half into 500 kΩ, and 10 V × 500 kΩ / 1.5 MΩ = 3.33 V. This is voltmeter loading.

Voltmeter and ammeter symbols

In a circuit diagram a voltmeter is a circle with a V, drawn across the part it measures, and an ammeter is a circle with an A, drawn in line with the wire.

Voltmeter symbol: a circle with a V V
Voltmeter
Ammeter symbol: a circle with an A A
Ammeter

Voltmeter vs ammeter

Try these circuits

Each runs on its own page without an account.

The multimeter circuit from the community

Use it in class

With the voltage circuit, ask students to change the right-hand resistor from 1 kΩ to 2 kΩ and measure it again: 6.667 V, as 10 V × 2 kΩ / 3 kΩ says.

With the current circuit, ask them to set the battery to 5 V: the ammeter reads 2.50 mA, 5 V / 2 kΩ.

Teachers can start a free classroom with up to 5 students and get the 7-day full-class trial when the first student joins.

Try it with your class

Frequently asked questions

How do I use a multimeter for the first time?

Turn the dial to what you want to measure, pick a range above the value you expect, touch the probes across the part (for current, put the meter in series) and read the display.

What is the difference between a voltmeter and an ammeter?

A voltmeter measures the voltage across a part and connects in parallel. An ammeter measures the current through a part and connects in series.

Why does my multimeter show OL?

The value is above the range you picked, or, for resistance and continuity, the path is open. Turn to a higher range or check the connection.

Why is my multimeter reading negative?

The red probe is on the more negative point. Swap the probes for a positive reading; nothing is damaged.

Is this multimeter simulator free?

Yes. The circuits on this page run free in your browser with no account. A free account lets you try the full lab, which then switches to a limited mode.

Practise on your own circuit

Open the lab, build a circuit and measure it.

Open the lab