Voltmeter Loading: a 1 MΩ Meter on a 1 MΩ + 1 MΩ Divider
A 10 V battery feeds a 1 MΩ + 1 MΩ divider. The inline voltmeter has a 1 MΩ input, so across the lower half it reads 3.33 V instead of 5 V: meter loading.
Aprende a usar un multímetro, con circuitos que puedes medir
¿Enseñas con circuitos?
Crea una clase, asigna un circuito a tus alumnos y revisa lo que entregan. Pruébalo gratis con una clase y hasta 5 alumnos.
Prueba gratis la demo de claseCómo funciona
A 10 V battery feeds two 1 MΩ resistors in series. Without a meter, the middle point sits at 5 V. The inline voltmeter across the lower resistor has a 1 MΩ input, so in parallel with that resistor it makes 500 kΩ, and the divider becomes 1 MΩ over 500 kΩ: 10 V × 500 kΩ / 1.5 MΩ = 3.33 V. The meter reads 3.33 V.
This is voltmeter loading: a meter changes the circuit it measures when its input resistance is not far above the circuit's. The lab's digital multimeter reads as an ideal meter and does not load the circuit.
Qué contiene
- 1× batería
- 2× resistencia (1 MΩ)
- Medido con voltímetro/amperímetro